top of page

Products > Solar Simulators > Filter For Solar Simulation

u17.png

(160-REC) Water Recirculating Cooler 900W capacity

Sku: 165-8010

Sciencetech's [160-REC] is a cooling water recirculator. It is designed to work with any of Sciencetech's liquid cooled solar cell chucks. This recirculator can maintain your sample at room temperature while sinking up to 900W of power from your light source.

-Dissipates up to 900W of thermal heat
-External fan cooled radiator system
-Cools to ambient temperature
-Real time sample temperature display (in °C or °F)
-Adjustable cooling ratea

u19.jpg

(BBT-3000) Detector, 4kW Power, Water Cooled, 100mm Aperture

Sku: 585-0004

4kW max average power, 100mm aperture, water-cooled. Doesn't require monitor, includes USB cable and PC-HP application software. 

Sensitivity 0.4 mW/W, 
rise time 7 sec, 
spectral range 0.19-20um.

u21.jpg

(PS/TC-1) Power Supply for Single Channel Detectors with TE Cooler

Sku: 590-0047

This power supply is designed to work with many of Sciencetech's detectors, specifically those with included Thermoelectric (TE) cooling. 
For full technical specifications, or for any questions, please contact your authorized Sciencetech technical sales staff member.

u23.jpg

(SSIVT-TU) Point-by-Point Irradiance and Temperature Measurement Upgrade for IV Testers

Sku: 175-9105

This upgrade includes the necessary hardware and software modifications to Sciencetech's SSIVT line of IV testers to allow real-time measurement of temperature, irradiance, and calculations of thermal co-efficients for each point of the IV curve.
Please note that this upgrade requires a Sciencetech IV tester in order to function, and will not work if a 3rd party tester is purchased from a different supplier.
Please speak with your authorized Sciencetech technical support staff member to discuss specifications and any additional details required.

u5.png

(UJP-100-LR-16) U-Jig package, 100x100mm target, 16bit DAQ

Sku: 179-9001

Target size: 100x100mm
DAQ: 16 bit
Detector size : 20x20mm (apertured to 12.5x12.5mm)
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 200x200x125

u5.png

(UJP-500-LR-16) U-Jig package, 500x500mm target, 16bit DAQ

Sku: 179-9003

Target size: 500x500mm
DAQ: 16 bit
Detector size : 20x20mm
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 800x800x125

u26.jpg

Preconfigured Host Computer System

Sku: 490-0128

A mid-grade PC using Windows software, these computers are pre-installed with all necessary Sciencetech software and has been used to test your particular system to ensure proper operation of all software packages.

u18.jpg

(BBT-03) Broadband Thermopile Detector - 3W

Sku: 585-0002

This Broadband Thermopile Detector allows the measurement of infrared light in the 0.19 – 20 µm range. This detector has a 12mm diameter sensor, measures up to 3 W with the maximum noise of 1 µW. Please note that this detector head requires either an external display controller or computer interface (sold separately) to show the measured power. The price shown includes the detector head, post, post holder, and base only.

u20.jpg

(FS-02) Light Intensity Stabilizer

Sku: 115-9021

The Light Intensity Stabilizer is a microprocessor based stand alone unit. It comes with a light sensor which is coupled to the light source using a fiber optic cable for electrical isolation. The unit is easy to install and operate and it is used to monitor the relative light intensity of a solar simulator or light source with the press of a button. It corrects long-term intensity fluctuations caused by changes in environmental or power conditions by automatically adjusting the power supply output in real time to maintain the same light intensity level. The Light Intensity Stabilizer uses relative intensity comparison to maintain light levels and does not compensate for lamp age.

u22.jpg

(SCI-SCC6-B) 6.5" x 6.5" (16.5 x 16.5cm) Solar Cell Chuck, Uncooled, Rear Contact

Sku: 165-8222

The SCI-SCC6-B cell chuck is an economical way of providing electrical connection to the back of your test cells. It is compatible with all of Sciencetech's probe systems except the SCP-MP-T and SCP-MP-G. It is not capable of vacuum hold down.
Working Area: 6" x 6"
Temperature Range: N/A
Power Input: N/A
Power Usage: N/A
Options: N/A

u24_edited.jpg

(TC-1000) Water Recirculating Chiller

Sku: 165-8265

Cooling capacity: 800W (2730BTU/hr) @ 25°C liquid/ambient
Temperature options: liquid set-point (1 to 50°C), optional external thermocouple set-point (1 to 149°C), liquid and ambient delta-T (± -50 to 50°C), external sensor and ambient delta-T (± -50 to 50°C).
Select only values you want displayed on the front 2-line OLED display (fixed or rotating)
Adjust pump speed with 10 level increments
Show pump impeller speed in RPM
Show coolant flow rate in LPM/GPM
Show condenser fan speed in RPM
Adjust audio alarm based on temperatures
Relay trigger can be configured as NO or NC and adjusted based on temperatures
Refrigerant: R-134a
Power input: 120VAC, 60Hz
Maximum power consumption @ ambient (approximate): 450W @ 25°C, 650W @ 35°C
Designed for an operational temperature range of 0-40°C (ambient and liquid)
Reservoir capacity: 3 liters
G 1/4 BSPP threads on back for fittings
NOTE: Requires 120VAC, 60Hz input power. Keep unit upright at all times, and for at least 24 hours before applying power to ensure sufficient oil reaches the compressor.


Weight 57.00 lb (25.86 kg)
Max Pressure @ 25°C 2kgf/cm2 (28.5psi)
Max Temperature 40°C (104°F)

u5.png

(UJP-350-LR-16) U-Jig package, 350x350mm target, 16bit DAQ

Sku: 179-9002

Target size: 350x350mm
DAQ: 16 bit
Detector size : 20x20mm 
Detector Type: SCI-REF-LR
Connectivity: 1 x USB2.0
Power Requirements: 120VAC x 4A / 220VAC x 2A
Dimensions: 600x600x125

u25.jpg

IV Test / PTS Temperature Measurement Upgrade

Sku: 175-9050

This is a modification to the Keithley unit used for IV Test measurements to allow the system to measure temperature at the same time as intensity. These Keithley units are used in all of Sciencetech's line of Photovoltaic Testing Systems, as well as our stand-alone IV Test units.
Please note that this system requires a calibrated reference cell to operate, and will not function with flash illumination systems.

bottom of page